Last updated:
Your central air conditioner is old, and in winter the same air handler heats with electric strips that make the bill jump every cold snap. The bedrooms feel close at night too. You want one system that handles all of it, and you’d like to know who files the permit down here.
Sweet Olive installs and replaces ducted air-source heat pumps in homes across Belle Chasse and the rest of our service area. Belle Chasse is in Plaquemines Parish, so the filing goes to the parish Permits Department, not to Jefferson Parish or City Hall in New Orleans. On the first visit we look at the attic air handler, test the ducts, check how air gets back to the return and look at the outdoor stand. Your written estimate names the equipment, the duct and return work, the electrical items and the parish permit steps.
For a system that is failing, the replacement page covers the choice; a house heated by a gas furnace is a conversion.
Inside a Lake Park heat pump replacement
A raised house, an old air conditioner that heated with strips, closed bedroom doors and a Plaquemines Parish filing.


- Location
- Lake Park, Belle Chasse
- Home
- Single-story raised home on piers, about 1,800 sq ft, three bedrooms
- System
- Nominal 3-ton variable-capacity heat pump
- Old system
- Central air with electric heat strips
- Return path
- Two jumper ducts added from bedrooms to the hall
- Outdoor unit
- Existing steel stand kept after checking
- Permit
- Plaquemines Parish
- Project price
- $8,950
- Duration
- 2 working days
The setting
Strip heat and stuffy bedrooms
The house was a single-story home raised on piers in Lake Park, about 1,800 square feet with three bedrooms. It cooled with an old central air conditioner and heated with electric strips in the attic air handler. With the bedroom doors shut at night, those rooms turned stuffy, because the only return was in the hall ceiling. The outdoor unit sat on a steel stand beside the steps.
The decision
A heat pump, and a way back for the air
The load calculation supported a nominal three-ton, variable-capacity heat pump, chosen to heat with the compressor and keep the strips for backup. The ducts tested tight, so they stayed. The closed-door problem was a return path, not capacity, so we added two jumper ducts from the bedroom ceilings to the hall instead of moving up a size.
- Dark circle, Air handler: on an attic platform, over a secondary drain pan
- Ochre square, Supply runs: dropping to ceiling registers
- Blue diamond, Central return: in the hall ceiling
- Yellow triangle, Jumper duct: from a closed bedroom to the hall
- Open ring, Line set and drain: along the outside wall
- Dark cross, Outdoor unit: on a raised stand, with its disconnect
The work
Attic first, then the stand
On day one we recovered the refrigerant, removed the old air handler and set the new one on its attic platform over a new secondary pan and float switch, then cut in the two jumper ducts with their ceiling grilles. On day two we set the outdoor unit on the existing stand, which checked out solid and level, and ran a new 30-foot line set, brazed under nitrogen, pressure-tested and evacuated.
The handover
Doors closed, air still moving
We set the thermostat to hold the heat strips back unless the heat pump needed help, tested the drain and float switch, and measured static pressure with the bedroom doors shut. Plaquemines Parish inspected after the work. The aim was heat from the compressor most of the winter, and bedrooms that stayed fresh with their doors closed.
A Plaquemines Parish permit
Belle Chasse sits across the parish line from the rest of the west bank.
The parish files and inspects
Belle Chasse is an unincorporated community and the largest in Plaquemines Parish. The parish Permits Department handles air-conditioning and heating permit applications, so your filing goes there before the work starts. Woodmere, which meets Belle Chasse at its northwest corner, belongs to Jefferson Parish and files there instead. The permit guide compares the offices, and your estimate states who obtains the permit.
Your electric account
Belle Chasse homes are generally on Entergy Louisiana accounts. The Energy Smart rebate is for Entergy New Orleans residential accounts, so we confirm your account before counting any incentive.

Strip heat or a heat pump?
Both heat the house; one does it with far less electricity on a mild morning.
Air conditioner with heat strips
The outdoor unit only cools. Winter heat comes from electric resistance strips in the air handler.
- Simple equipment
- Every degree of heat comes from the strips
- Bills climb in cold snaps
Heat pump with backup strips
The outdoor unit cools in summer and reverses in winter, moving heat into the house.
- The compressor does most of the heating
- Strips kept for backup on the coldest mornings
- Needs a thermostat that holds the strips back
Replacing the air conditioner with a heat pump keeps the strips as backup and lets the compressor carry the winter.
Holding the strips back
The thermostat has to know the difference between heat pump heat and strip heat, or it brings the strips on too readily. We set it up for the equipment’s stages and backup heat; the thermostat guide explains what to look for, and the operating cost guide covers what changes on the bill.
Raised houses: attic, return and stand
Where a house is raised on piers, the work splits between the attic and the yard.

A way back to the return
A single return in the hall ceiling leaves closed bedrooms starved of air. Before moving up a size, we measure with the doors shut. If the rooms pressurize, a jumper duct from each bedroom ceiling to the hall gives the air a way back. Crushed or loose runs go on the estimate as ductwork repair.
The stand and the line set
On a raised house the outdoor unit often sits on a stand. Heating and cooling equipment isn’t built to sit in floodwater, and the parcel’s requirements decide the height. We check the stand for soundness, level and footprint, and the placement guide covers manufacturer clearances.
Budgeting a Belle Chasse replacement
The parish line doesn't change our range.
Sweet Olive's typical range for a residential ducted heat pump replacement is $4,250 to $11,750. We set your price after the site visit and write it into your estimate line by line, with the Plaquemines Parish permit steps shown for your address.
What moves a Belle Chasse price
- Equipment. Capacity from the load calculation, and single-stage or variable-capacity.
- Return path. Jumper ducts or a bedroom return, when the closed-door test calls for them.
- The stand. Reused after checking, or replaced as its own line.
- Attic work. A new secondary pan and float switch under the air handler.
- Controls. A thermostat set up for stages and backup heat.