# Heat Pump Installation Belle Chasse LA | Strip Heat Swaps

> Ducted heat pump installation and replacement for Belle Chasse homes, filed with Plaquemines Parish and planned around strip heat, attics and stands. Ask us.

URL: https://sweetolivenolaheatpumps.com/service-areas/belle-chasse/

Cooling with an old central air conditioner and heating with electric strips? In Belle Chasse we plan the heat pump that replaces both around your attic, your return path and the outdoor stand, file with Plaquemines Parish, and put the whole scope in one written estimate.

Heat pump on a raised steel stand beside the side stairs of a Belle Chasse home.

## What brings Belle Chasse homeowners to us

### Heating with strips

The air handler heats with electric resistance strips, and winter bills show it. A heat pump does most of that heating with the compressor instead.

### Closed doors, stuffy bedrooms

Bedrooms feel close at night with the doors shut. A single hall return is a likely cause, and a return path is cheaper than a bigger system.

### A unit up on a stand

The outdoor unit sits on a raised stand. We check whether it is sound and level enough to carry the new equipment.

### A new parish to file with

You've moved from the other side of the river and expect a Jefferson or New Orleans permit. Belle Chasse files with Plaquemines Parish.

Last updated: November 18, 2026

Your central air conditioner is old, and in winter the same air handler heats with electric strips that make the bill jump every cold snap. The bedrooms feel close at night too. You want one system that handles all of it, and you’d like to know who files the permit down here.

[Sweet Olive](https://sweetolivenolaheatpumps.com/) installs and replaces ducted air-source heat pumps in homes across Belle Chasse and the rest of [our service area](https://sweetolivenolaheatpumps.com/service-areas/). Belle Chasse is in Plaquemines Parish, so the filing goes to the parish Permits Department, not to Jefferson Parish or City Hall in New Orleans. On the first visit we look at the attic air handler, test the ducts, check how air gets back to the return and look at the outdoor stand. Your written estimate names the equipment, the duct and return work, the electrical items and the parish permit steps.

For a system that is failing, the [replacement page](https://sweetolivenolaheatpumps.com/heat-pump-replacement/) covers the choice; a house heated by a gas furnace is a [conversion](https://sweetolivenolaheatpumps.com/heat-pump-conversion/).

## Inside a Lake Park heat pump replacement

A raised house, an old air conditioner that heated with strips, closed bedroom doors and a Plaquemines Parish filing.

Before

After

- **Location**: Lake Park, Belle Chasse
- **Home**: Single-story raised home on piers, about 1,800 sq ft, three bedrooms
- **System**: Nominal 3-ton variable-capacity heat pump
- **Old system**: Central air with electric heat strips
- **Return path**: Two jumper ducts added from bedrooms to the hall
- **Outdoor unit**: Existing steel stand kept after checking
- **Permit**: Plaquemines Parish
- **Project price**: $8,950
- **Duration**: 2 working days

The setting

### Strip heat and stuffy bedrooms

The house was a single-story home raised on piers in Lake Park, about 1,800 square feet with three bedrooms. It cooled with an old central air conditioner and heated with electric strips in the attic air handler. With the bedroom doors shut at night, those rooms turned stuffy, because the only return was in the hall ceiling. The outdoor unit sat on a steel stand beside the steps.

The decision

### A heat pump, and a way back for the air

The load calculation supported a nominal three-ton, variable-capacity heat pump, chosen to heat with the compressor and keep the strips for backup. The ducts tested tight, so they stayed. The closed-door problem was a return path, not capacity, so we added two jumper ducts from the bedroom ceilings to the hall instead of moving up a size.

- **Air handler**: on an attic platform, over a secondary drain pan
- **Supply runs**: dropping to ceiling registers
- **Central return**: in the hall ceiling
- **Jumper duct**: from a closed bedroom to the hall
- **Line set and drain**: along the outside wall
- **Outdoor unit**: on a raised stand, with its disconnect

A raised single-story house in section: attic air handler, ceiling registers, the hall return and the jumper ducts that let closed bedrooms breathe.

The work

### Attic first, then the stand

On day one we recovered the refrigerant, removed the old air handler and set the new one on its attic platform over a new secondary pan and float switch, then cut in the two jumper ducts with their ceiling grilles. On day two we set the outdoor unit on the existing stand, which checked out solid and level, and ran a new 30-foot line set, brazed under nitrogen, pressure-tested and evacuated.

The handover

### Doors closed, air still moving

We set the thermostat to hold the heat strips back unless the heat pump needed help, tested the drain and float switch, and measured static pressure with the bedroom doors shut. Plaquemines Parish inspected after the work. The aim was heat from the compressor most of the winter, and bedrooms that stayed fresh with their doors closed.

## A Plaquemines Parish permit

Belle Chasse sits across the parish line from the rest of the west bank.

### The parish files and inspects

Belle Chasse is an unincorporated community and the largest in Plaquemines Parish. The parish Permits Department handles air-conditioning and heating permit applications, so your filing goes there before the work starts. [Woodmere](https://sweetolivenolaheatpumps.com/service-areas/woodmere/), which meets Belle Chasse at its northwest corner, belongs to Jefferson Parish and files there instead. The [permit guide](https://sweetolivenolaheatpumps.com/guide/heat-pump-permits/) compares the offices, and your estimate states who obtains the permit.

### Your electric account

Belle Chasse homes are generally on Entergy Louisiana accounts. The Energy Smart rebate is for Entergy New Orleans residential accounts, so we confirm your account before counting any incentive.

Electrical connections on an outdoor unit, the kind of work an inspector looks at.

## Strip heat or a heat pump?

Both heat the house; one does it with far less electricity on a mild morning.

Air conditioner with heat strips

The outdoor unit only cools. Winter heat comes from electric resistance strips in the air handler.

- Simple equipment
- Every degree of heat comes from the strips
- Bills climb in cold snaps

Heat pump with backup strips

The outdoor unit cools in summer and reverses in winter, moving heat into the house.

- The compressor does most of the heating
- Strips kept for backup on the coldest mornings
- Needs a thermostat that holds the strips back

Replacing the air conditioner with a heat pump keeps the strips as backup and lets the compressor carry the winter.

### Holding the strips back

The thermostat has to know the difference between heat pump heat and strip heat, or it brings the strips on too readily. We set it up for the equipment’s stages and backup heat; the [thermostat guide](https://sweetolivenolaheatpumps.com/guide/heat-pump-thermostat-compatibility/) explains what to look for, and the [operating cost guide](https://sweetolivenolaheatpumps.com/guide/heat-pump-operating-cost/) covers what changes on the bill.

## Raised houses: attic, return and stand

Where a house is raised on piers, the work splits between the attic and the yard.

An attic plenum with insulated supply runs heading to the rooms below.

### A way back to the return

A single return in the hall ceiling leaves closed bedrooms starved of air. Before moving up a size, we measure with the doors shut. If the rooms pressurize, a jumper duct from each bedroom ceiling to the hall gives the air a way back. Crushed or loose runs go on the estimate as [ductwork repair](https://sweetolivenolaheatpumps.com/heat-pump-ductwork-repair/).

### The stand and the line set

On a raised house the outdoor unit often sits on a stand. Heating and cooling equipment isn’t built to sit in floodwater, and the parcel’s requirements decide the height. We check the stand for soundness, level and footprint, and the [placement guide](https://sweetolivenolaheatpumps.com/guide/heat-pump-outdoor-unit-placement/) covers manufacturer clearances.

## Budgeting a Belle Chasse replacement

The parish line doesn't change our range.

**Sweet Olive's typical range for a residential ducted heat pump replacement is $4,250 to $11,750.** We set your price after the site visit and write it into your estimate line by line, with the Plaquemines Parish permit steps shown for your address.

What moves a Belle Chasse price

- **Equipment.** Capacity from the load calculation, and single-stage or variable-capacity.
- **Return path.** Jumper ducts or a bedroom return, when the closed-door test calls for them.
- **The stand.** Reused after checking, or replaced as its own line.
- **Attic work.** A new secondary pan and float switch under the air handler.
- **Controls.** A thermostat set up for stages and backup heat.

## How a Belle Chasse job usually runs

Five steps, with the Plaquemines filing built in.

1. Send the address The address confirms the parish. Add what heats the house now and a photo of the air handler label if you can.
2. We visit Rooms with doors open and shut, the attic air handler, ducts, return path, panel and the outdoor stand.
3. Written estimate Equipment, any return-path or duct work, the stand, electrical items, the Plaquemines Parish permit steps and exclusions.
4. Permit and work days The permit is handled as your estimate states, then the work days, attic work first.
5. Startup and inspection Static pressure with doors shut, charge, drain and float switch, strip-heat settings, then the parish inspection.

## Around Belle Chasse

Permits: Plaquemines Parish. Electric service: Entergy Louisiana, confirmed for your address.

Neighborhoods

- Lake Park
- Oak Park
- Riverbend

Landmarks

- Naval Air Station Joint Reserve Base New Orleans
- Belle Chasse Public Library
- Belle Chasse Auditorium

Main routes

- Louisiana Highway 23

Belle Chasse and the communities around it that we serve. [Open the area in Google Maps](https://www.google.com/maps/search/?api=1&query=Belle%20Chasse%2C%20Louisiana)

## Questions from Belle Chasse

### Which office handles a heat pump permit in Belle Chasse?

Belle Chasse is in Plaquemines Parish, and the parish Permits Department takes air-conditioning and heating permit applications. That is a different office from Jefferson Parish next door or the City of New Orleans. Your written estimate states who obtains the permit and when the inspection happens.

### Will replacing strip heat with a heat pump lower my winter bills?

It usually lowers the electricity used for heating, because a heat pump moves heat rather than making it from resistance strips. How much depends on the equipment, the house, your thermostat habits and your rate, so we don't promise a figure. The strips stay as backup for the coldest mornings.

### What does a heat pump replacement cost in Belle Chasse?

The same as anywhere we work. Our typical range for a residential ducted heat pump replacement is $4,250 to $11,750. The parish line doesn't change it. A return path, a new stand or a longer line set are what move your figure. We set it after the visit and write each line into your estimate.

### Can the old outdoor stand be reused?

Sometimes. We check that it is solid, level, anchored and tall enough for the parcel's requirements, and that the new unit's footprint fits on it. If it passes, it stays; if not, a new stand goes on your estimate as its own line.

### Why are my bedrooms stuffy when the doors are closed?

Supply air goes into the room, but with the door shut it has no easy way back to a return in the hall, so the room pressurizes and gets less air. A jumper duct or a return in the room gives it a path back. We measure it with the doors shut before recommending one.