# Heat Pump Repair New Orleans | Diagnosed First

> Heat pump not cooling, not heating, iced over or cycling on and off? We find the cause first, then price the repair for your New Orleans home. Tell us about it.

URL: https://sweetolivenolaheatpumps.com/heat-pump-repair/

Warm air from the vents in July, a house that won't warm up on a January morning, or a system that starts and stops every few minutes? We test before we replace anything, explain what failed, and price the repair before we start it.

Technician testing the electrical compartment of an outdoor heat pump unit beside a raised Mid-City house.

- Repairs on ducted heat pumps in homes
- Tested before any part is changed
- Typical range $161 to $661
- Major components priced on their own

Last updated: November 18, 2026

The registers blow warm air on a July afternoon. Or the house won’t warm up on a cold morning while the outdoor unit sits under a crust of ice. Or the system starts, stops and starts again every few minutes. Each of those can come from more than one fault, which is why the first thing a repair needs is a diagnosis, not a guess.

[Sweet Olive](https://sweetolivenolaheatpumps.com/) repairs ducted heat pumps in homes [across New Orleans](https://sweetolivenolaheatpumps.com/service-areas/). On a repair visit we test before we replace anything: electrical readings at the outdoor unit and the air handler, the drain, the controls and, where the symptoms point there, the refrigerant side. We explain what failed and price the repair before we start it.

If the fault turns out to be a compressor or a coil on a worn system, we price a [replacement](https://sweetolivenolaheatpumps.com/heat-pump-replacement/) beside the repair so you can compare. If nothing is wrong yet and you want to know where the system stands, a [heat pump inspection](https://sweetolivenolaheatpumps.com/heat-pump-inspection/) is the better visit.

## A typical Mid-City heat pump repair

An August afternoon, warm air from the registers and an outdoor fan that stood still: what the repair visit found before any part was changed.

- **Location**: Mid-City, New Orleans
- **Home**: Raised single-story home, about 1,500 sq ft, three bedrooms
- **System**: Nominal 3-ton single-stage heat pump, closet air handler
- **Symptom**: Warm air from the vents; outdoor fan not turning
- **Parts**: 45/5 µF dual-run capacitor, 30-amp two-pole contactor
- **Also found**: Condensate line partly blocked; cleared and flushed
- **Project price**: $385
- **Duration**: One visit, about 3 hours

The call

### Warm air on an August afternoon

The home was a raised, single-story house in Mid-City, about 1,500 square feet, with a three-ton heat pump and an air handler in a hall closet. On a hot afternoon the registers blew warm air. Outside, the unit hummed, the fan blade sat still and the compressor clicked off after a few minutes.

The diagnosis

### Tested before anything was replaced

We shut off power, discharged and tested the dual-run capacitor and found it reading well below its 45 and 5 microfarad rating. The contactor points were pitted and burned. The fan motor turned freely and its windings tested sound, and the compressor's windings read normal, so the fault sat in the start and switching parts, not in a major component.

- **Fan motor**: windings test sound; kept
- **Compressor**: windings read normal; kept
- **Power from the disconnect**: lands on the contactor's line side
- **Contactor, 30 A two-pole**: pitted points; replaced
- **Dual-run capacitor, 45/5 µF**: tested weak; replaced. HERM runs to the compressor's start terminal, FAN to the fan motor, C to the run side of the contactor
- **Shaded yellow**: replaced on this visit

The outdoor unit with its service panel off. The capacitor and contactor we replaced are shaded; the fan motor and compressor stayed, because their windings tested sound.

The repair

### Two parts, then a full run

We replaced the capacitor with a matching 45/5 microfarad part and the contactor with a 30-amp two-pole one, then restarted the system and measured amp draw on the compressor and fan against the nameplate. While it ran, we found water sitting high in the condensate trap, so we cleared the line, flushed it and confirmed the float switch shut the system off at the right level.

The close

### Readings on the record

After a full cooling run we wrote the capacitor value, the amp draws and the temperature drop across the coil on the visit record and left a copy with the owner. The price covered the diagnostic visit and both parts. The aim was a system that cooled again, with readings on file for the next visit to compare against.

## What is your heat pump doing?

A symptom points to a few possible causes, never to one. This is what each one can mean, and what you can safely check before we arrive.

| Symptom | What it can mean | What you can check first |
| --- | --- | --- |
| Warm air in cooling | A failed capacitor or contactor, a stopped outdoor fan, low refrigerant, a dirty coil | The thermostat is set to cool, and the outdoor unit is running |
| No heat, or heat that never catches up | A reversing valve or defrost fault, low charge, a heat strip that won’t come on | The thermostat is set to heat, and the outdoor coil isn’t solid ice |
| Short cycling | Oversized equipment, a thermostat in the wrong spot, a tripped safety switch, low airflow | A clean filter and open registers |
| Water on the floor or ceiling | A blocked condensate drain, a rusted pan, a missing float switch | Turn the system off to stop the water |
| Loud buzzing, grinding or rattling | A failing motor or capacitor, loose panels, debris in the fan | Nothing; switch it off if the noise is new and harsh |
| Breaker trips | A shorted motor, a failing compressor, a loose or burned connection | Reset once; if it trips again, leave it off |

Common heat pump symptoms, their possible causes and the safe checks to make first.

The checks to leave alone

Please don’t open the panels, jump a switch or add refrigerant from a store kit. Those steps can hide the real fault, damage the compressor or leave live wiring exposed. Our [warning signs guide](https://sweetolivenolaheatpumps.com/guide/heat-pump-warning-signs/) covers what to watch for between visits.

## What happens on a repair visit

We start with the simple causes, then move to the parts that need meters and gauges.

Inside the closet: the blower, the coil, the drain trap and the heat strip all live in the air handler.

### Outside: power, switching and the fan

With the power off, we check the disconnect, the contactor and the capacitor, then restart the unit and measure amp draw on the compressor and the fan motor against the nameplate. A capacitor that reads below its rating, burned contactor points or a motor drawing too much current each tell a different story.

### Inside: airflow, drain and backup heat

At the air handler we look at the filter, the blower, the coil and the drain, then test the float switch and, in heat mode, the heat strip. Low airflow from a clogged filter or a dirty coil can freeze the coil in summer and overheat the system in winter, so we rule it out before blaming the refrigerant.

### The refrigerant side, when the symptoms point there

If the electrical side checks out, we connect gauges and read pressures and line temperatures to see whether the charge, the metering device or the compressor is at fault. Low charge always means a leak somewhere; topping it up without finding the leak only delays the next call. A leak repair is brazed under nitrogen, pressure-tested and evacuated to a micron reading before the charge goes back in.

### Before we fix anything

We explain what we found, what it rules out and what we still can’t tell. Then we price the repair. Nothing is replaced until you approve it.

An outdoor unit on its pad, where most electrical repairs happen.

## Heat mode problems that aren't always faults

A heat pump heats differently from a gas furnace, and a few of its normal habits look like trouble.

54.3°F

Average daily temperature in January at the New Orleans airport, from National Weather Service climate normals

Most winter days here are mild for a heat pump. The cold snaps are when the heat strip and the defrost cycle earn their keep.

### Air that feels cooler than a furnace

A heat pump delivers a steady stream of warm air rather than short blasts of hot air, so a hand on the register can feel cool even while the room warms. That is normal. A house that keeps losing ground on a cold morning is not.

### Frost, steam and the defrost cycle

On cold, damp mornings frost forms on the outdoor coil. The system reverses for a few minutes to melt it, which can send steam off the unit and cool air from the vents. If the coil stays iced over, the defrost control, a sensor or the charge needs checking. Our [cold weather guide](https://sweetolivenolaheatpumps.com/guide/heat-pump-cold-weather/) explains how the backup heat fits in.

The thermostat decides when the backup heat runs, so a wrong setting can look like a fault.

## When a repair stops being the best answer

Most repairs are small. A few are the moment to look at the whole system.

### Major components on a worn system

A failed compressor, outdoor coil, indoor coil or reversing valve is priced on its own, and on older equipment the bill can approach a large share of a new system. That is when we give you both prices: the repair, and a [replacement](https://sweetolivenolaheatpumps.com/heat-pump-replacement/) sized from your rooms. The [repair or replace guide](https://sweetolivenolaheatpumps.com/guide/heat-pump-repair-or-replace/) walks through the comparison, and the [components guide](https://sweetolivenolaheatpumps.com/guide/heat-pump-components/) explains what each part does.

### Repeat faults that point somewhere else

A capacitor that fails every summer, a coil that freezes again after a recharge, or a drain that overflows twice a season usually has a cause outside the part itself: restricted ducts, an oversized system, a poor drain slope or high static pressure. If we see a pattern, we tell you, and a [ductwork repair](https://sweetolivenolaheatpumps.com/heat-pump-ductwork-repair/) or regular [maintenance](https://sweetolivenolaheatpumps.com/heat-pump-maintenance/) may fix more than another part would.

## What a repair costs

The diagnosis sets the price, so you see it before any work starts.

**Sweet Olive's typical range for a residential heat pump repair is $161 to $661.** The diagnostic visit is its own line, and a major component such as a compressor or an indoor coil is priced separately once the failure is confirmed. We price the repair before we start and write it on your estimate.

What moves a repair price

- **The part.** A capacitor or contactor costs far less than a fan motor or a defrost control.
- **Refrigerant work.** Finding and brazing a leak, the pressure test, the evacuation and the charge add time and material.
- **Access.** An air handler in a tight attic or behind a finished closet takes longer to reach.
- **The permit, where it applies.** The City of New Orleans mechanical permit covers repairing heating and cooling equipment as well as installing it; your estimate says when a repair needs one. Our [permit guide](https://sweetolivenolaheatpumps.com/guide/heat-pump-permits/) covers each office.

## What a repair visit includes

Every visit covers the diagnosis; the repair itself depends on what we find.

- A look at the thermostat settings, the filter and the breakers before anything is opened
- Electrical readings at the outdoor unit and the air handler, including capacitors, contactors and motor amp draw
- Operating checks in the mode that is failing, cooling or heat
- Refrigerant pressures and temperatures when the symptoms point to the refrigerant side
- A check of the condensate drain, trap, secondary pan and float switch
- The cause explained in plain terms, with what we know and what we can't yet tell
- The repair price before we start, with any major component as its own line
- A run test after the repair, with the readings left with you

## Repair, a bigger repair, or a replacement

Most calls end with a part and a run test. Some end with a decision. These are the three outcomes.

*A routine repair, a major-component repair and a replacement compared*

| Outcome | Typical parts | How it is priced | What to weigh |
| --- | --- | --- | --- |
| Routine repair | Capacitor, contactor, fan motor, sensor, defrost control, drain, thermostat | Within the typical repair range, after the diagnosis | Usually the right call on a sound system |
| Major-component repair | Compressor, outdoor coil, indoor coil, reversing valve | As its own line, once the failure is confirmed | The age and condition of the rest of the system, and whether it ever kept the house comfortable |
| Replacement | Matched outdoor unit, air handler and controls | From the house, after a load calculation and duct test | Sizing, ducts and wiring get a fresh look, at a higher price |

We recommend the smallest repair that fixes the fault. When the fault is a major component on a worn system, we price the replacement beside it so you can compare.

## How a repair call runs

Five stops from your first message to the run test.

1. Tell us the symptom What the system does, in which mode, since when, and anything you have already tried. A photo of the outdoor nameplate helps.
2. We look before we open Thermostat, filter, breakers and drain, then the outdoor unit and the air handler.
3. We test and explain Electrical readings and operating checks narrow the cause, and we explain what failed and what it means.
4. You approve the price The repair is priced before we start, with any major component shown on its own line.
5. Repair and run test The part goes in, the system runs in the failing mode, and the readings are left with you.

## Questions we hear about this work

### Why does my heat pump blow cool air in heat mode for a few minutes?

It is often the defrost cycle. On cold, damp mornings frost builds on the outdoor coil, and the system briefly reverses to melt it, so the air from the vents feels cool and you may see steam outside. That is normal for a few minutes. If it lasts much longer, or the house never warms, the defrost control, a sensor or the refrigerant charge may be at fault.

### Is ice on the outdoor unit a sign of a problem?

A light frost that clears every so often in heat mode is normal. A coil that stays encased in ice, ice on the top of the unit, or ice on the copper lines in summer cooling is not. It can mean low airflow, a defrost fault or a refrigerant problem. Switch the system off and call us rather than chipping or hosing the ice off.

### Should I keep resetting the breaker if the heat pump trips it?

No. One reset after a storm or a power cut is reasonable. A breaker that trips again is protecting the wiring from a fault, such as a shorted motor, a failing compressor or a loose connection. Leave it off and tell us when it trips and what was running, which helps narrow the cause.

### Why is water dripping from the ceiling under my air handler?

The usual cause is a blocked condensate drain overflowing the pan, or a secondary pan with no float switch to shut the system off. A rusted pan or a disconnected drain line can do the same. Turn the system off at the thermostat to stop the water, then call us. We clear the drain and check that the pan and the float switch do their job.

### Is it worth repairing an older heat pump?

Age alone doesn't decide it. A capacitor or a contactor on an old system can still be a sensible repair. A failed compressor or coil on a worn system that never kept the house comfortable is the point to compare repair and replacement prices. We give you both when the fault calls for it.