# Heat Pump Installation New Orleans | Sized Room by Room

> New ducted heat pump installation for New Orleans homes, planned room by room with the ducts, wiring and permit in one written estimate. Ask for your estimate.

URL: https://sweetolivenolaheatpumps.com/heat-pump-installation/

Window units in three rooms and the kitchen still sticky? A house that never had central air, or a back addition the old system can't reach? We plan a ducted heat pump around your rooms, your attic and your panel, then put the whole scope in one written estimate.

New heat pump outdoor unit on a two-foot steel stand beside a raised Gentilly bungalow.

- Ducted air-source heat pumps for homes
- Sized room by room, not by square footage
- Typical range $4,250 to $11,750
- Written estimate after the visit

Last updated: November 18, 2026

Maybe the house has never had central air and three window units are doing their best. Maybe a back addition or a converted porch never got cooling at all. Either way, a new ducted system has to be planned from the house up: where the air handler fits, how air reaches every room and gets back, and what your panel can carry.

[Sweet Olive](https://sweetolivenolaheatpumps.com/) installs ducted air-source heat pumps in homes [across New Orleans](https://sweetolivenolaheatpumps.com/service-areas/). On the first visit we measure the rooms, look for a duct route through the attic or crawlspace, and check your panel and the spot outside where the unit would sit. You then get a written estimate that names the equipment, the ductwork, the wiring and the permit steps, and prices that exact scope.

One set of equipment does two jobs: it cools and dries the house through the long summer, then runs in reverse to heat it on cold mornings. If you already have a central system that is failing, our [heat pump replacement](https://sweetolivenolaheatpumps.com/heat-pump-replacement/) page covers that decision, and [furnace to heat pump conversion](https://sweetolivenolaheatpumps.com/heat-pump-conversion/) covers houses heated by gas today.

## A typical Gentilly heat pump installation

Three window units, no ducts and a kitchen that never cooled: the first ducted system we put into a raised Gentilly bungalow.

Before

During the work

- **Location**: Gentilly, New Orleans
- **Home**: Raised single-story bungalow, about 1,400 sq ft, three bedrooms
- **System**: Nominal 2.5-ton two-stage ducted heat pump
- **Ductwork**: 8 supply runs, 1 central return, 3 jumper ducts
- **Air handler**: Horizontal, on an attic platform over a secondary pan
- **Outdoor unit**: 24-inch stand, 25-foot line set
- **Project price**: $11,350
- **Duration**: 3 working days

The house

### Three window units and no ducts

The house was a raised, single-story bungalow of about 1,400 square feet with three bedrooms, cooled by three window units and heated with portable heaters. The kitchen, the bath and the back bedroom had no unit at all, so the house never felt dry. There were no ducts, the ceilings were plaster on lath, and the only way into the attic was a pull-down stair in the hall.

The decision

### An attic air handler and a return for every room

The room-by-room load calculation supported a nominal two-and-a-half-ton, two-stage system. We put a horizontal air handler on a platform in the attic rather than give up the hall closet, choosing a cabinet that passed through the 25-by-54-inch stair opening. It sat over a finished ceiling, so a secondary drain pan and float switch went under it. Eight insulated supply runs fed ceiling registers, one return drew from the hall, and three jumper ducts let closed bedrooms send air back to it.

- **Air handler**: on an attic platform, over a secondary drain pan
- **Supply runs**: dropping to ceiling registers
- **Central return**: in the hall ceiling
- **Jumper duct**: from a closed bedroom to the hall
- **Line set and drain**: along the outside wall
- **Outdoor unit**: on a raised stand, with its disconnect

The layout in section: attic air handler, ceiling registers, a hall return, a jumper duct and the outdoor unit on its stand.

The work

### Three working days, one room at a time

On day one we set the platform, the air handler and the supply plenum, and ran the ducts from walk boards. On day two we cut the plaster openings one room at a time under dust sheeting, set the outdoor unit on a 24-inch stand above a low spot where rain collected, and ran the 25-foot line set and the drain while an electrician added two circuits and the disconnect. Day three was the nitrogen pressure test, evacuation, charge, airflow readings and the thermostat walk-through.

The result

### One system for the whole house

The window units came out and the sashes closed again. Every room got supply air and a path back to the return, and we set the low stage to run long on muggy days and pull moisture out of the whole house. The startup readings stayed with the owner, and the City inspection followed the work.

## Is a new ducted system right for your house?

A new installation fits when the house has no central system, or when part of it has never been served. The deciding question is whether there's a sensible path for ducts and a place for the air handler.

Good signs we look for on the first visit

- An attic with walkable headroom, or a crawlspace that stays dry, for the supply runs
- A hall or central spot where one return can draw air from the whole house
- Open spaces in the panel, or a clear path to add them
- An outdoor spot with room around the coil and firm, dry footing

A deep porch and tall front rooms: the spaces a first duct layout has to reach.

### When a different service fits better

If you have a gas furnace you want to keep for backup heat, a heat pump can be paired with it; our [dual-fuel guide](https://sweetolivenolaheatpumps.com/guide/dual-fuel-heat-pump-systems/) explains how the two share the work. Ductless mini splits are a different kind of system that we don’t install, so if the house has no route for ducts at all, that’s the type of system to ask about.

## What happens on the first visit

We spend most of the visit in the places that decide the layout, not just the living room. Six stops cover it.

- **The rooms.** Windows, sun, ceiling height, insulation and air leaks all feed the load calculation.
- **The attic or crawlspace.** Headroom, the size of the opening, which way the joists run and how deep the insulation is.
- **The return path.** Where one central return can draw air, and how closed bedrooms send air back to it.
- **The panel.** Its rating, its open spaces and what is already on it.
- **The outdoor spot.** Clearances, footing, where water goes after a storm, and the line-set route into the house.
- **The thermostat.** An inside wall away from sun and supply registers.

- **Each room**: windows, sun and ceiling height for the load calculation
- **Attic opening**: headroom and joists
- **Return location**: where a central return can draw air
- **Electrical panel**: rating, open spaces and existing load
- **Outdoor spot**: footing and drainage
- **Thermostat**: on an inside wall

The six stops of a first visit, keyed on a three-bedroom plan.

### If part of the house already has ducts

An addition or an old system sometimes leaves ducts behind. We test them for leakage and measure static pressure before deciding whether to reuse them, because a leaky or undersized run can starve a new system as surely as no duct at all. Our [ductwork guide](https://sweetolivenolaheatpumps.com/guide/heat-pump-ductwork/) shows what those tests find. You get a written estimate built from these measurements, not a price read off the square footage.

## How we size the system for your rooms

Capacity comes from a load calculation, not from the square footage or the size of the unit next door.

84°F

Average daily temperature in August at the New Orleans airport, from National Weather Service climate normals

Add the humidity that comes with it, and a cooling system here spends much of the year removing moisture as well as heat.

### Why bigger isn't safer

A load calculation (ACCA Manual J) adds up the heat coming into each room through its windows, walls, ceiling and air leaks. Oversized equipment cools the air fast, satisfies the thermostat and shuts off before the coil has run long enough to pull much water out. The house reaches 74 degrees and still feels clammy. Right-sized equipment runs longer, steadier cycles, and that is what dries the air.

Open front rooms share one load; each room that feeds it gets its own figures.

A two-stage system needs a thermostat that can call for each stage and for the backup heat.

### Single-stage, two-stage or variable-speed

The load sets the capacity, and the capacity then tells us whether your ducts can carry the airflow it needs. Single-stage equipment runs at full output or not at all. Two-stage and variable-speed equipment runs at low output most of the time and steps up on the hottest afternoons, which means longer, quieter runs and more moisture removed. It costs more, and the thermostat has to match it. Our [comparison guide](https://sweetolivenolaheatpumps.com/guide/single-stage-vs-variable-speed-heat-pumps/) goes further.

### Backup heat and efficiency ratings

Winters here are short and mild, but cold snaps still come. A small electric heat strip in the air handler covers those hours and warms the air while the outdoor coil defrosts, so we size it from your heating load, not at the biggest strip the cabinet accepts. SEER2 and HSPF2 rate cooling and heating efficiency; a higher rating lowers running cost at the same load, but it can’t fix an oversized unit or leaky ducts. More in our [sizing guide](https://sweetolivenolaheatpumps.com/guide/heat-pump-sizing/) and [humidity guide](https://sweetolivenolaheatpumps.com/guide/heat-pump-humidity-new-orleans/).

## Wiring, permits and where the outdoor unit goes

Three things outside the equipment box decide whether installation day goes smoothly: the circuits, the permit and the spot for the outdoor unit.

| What we plan | What we check | Why it matters |
| --- | --- | --- |
| New circuits | The panel’s rating, open spaces and existing load | The heat pump and the backup heat each need a dedicated circuit sized to the nameplate |
| Outdoor disconnect | A spot within sight of the unit | It lets the unit be shut off safely for service |
| Control wiring | Thermostat terminals for each stage and the backup heat | The controls decide when the heat strip runs; miswired, it runs far too often |
| Line set | Length and route against the manufacturer’s limits | Line size and length affect the refrigerant charge and the capacity you get |
| Pad or stand | Footing, height and clearances | It keeps the coil breathing and the unit above standing water |

What we plan for the electrical and outdoor side, and why it matters.

### The permit for your address

The City of New Orleans requires a mechanical permit to install heating and cooling equipment. Jefferson Parish, St. Bernard Parish and the cities around us run their own permit offices. Your written estimate states who obtains the permit and when the inspection happens, and the work days are scheduled around it. Our [permit guide](https://sweetolivenolaheatpumps.com/guide/heat-pump-permits/) walks through each office.

### Where the outdoor unit can sit

Manufacturers set clearances around the coil and in front of the service panel. On a low lot we raise the unit on a stand so it sits above water that collects after heavy rain. In a local historic district the guidelines favour a rear-yard spot screened from the street, and the work may need review first; our [placement guide](https://sweetolivenolaheatpumps.com/guide/heat-pump-outdoor-unit-placement/) shows the options. The [electrical readiness guide](https://sweetolivenolaheatpumps.com/guide/heat-pump-electrical-readiness/) covers the circuit side in more depth.

An outdoor unit on its pad, with the disconnect and line set close by.

## From the first day of work to startup

Each stage depends on the one before it, so we keep them in this order.

### Air handler and ducts first

The air handler goes in its closet or on an attic platform, and the plenum and duct runs are built out from it. Every connection is sealed with mastic. Where the cabinet sits above a finished ceiling, a secondary drain pan with a float switch goes under it, so a blocked drain shuts the system off instead of staining the ceiling. Our [components guide](https://sweetolivenolaheatpumps.com/guide/heat-pump-components/) shows what each part does.

### Then the outdoor unit and the refrigerant lines

The pad or stand goes in, the unit is set, and the copper line set is run, supported and insulated along its route. We braze the joints while nitrogen flows through the pipe, which keeps scale from forming inside the lines where it could later block the metering device.

An air handler in its closet, with the drain trap and insulated duct connections in view.

Every line on the startup record is checked before you take over the thermostat.

### Pressure test and evacuation

Before any refrigerant goes in, we hold the new piping under nitrogen pressure to prove it is tight. Then a vacuum pump pulls the lines down while a micron gauge confirms the air and moisture are out. Skipping either step can leave a slow leak or moisture in the system that shows up months later.

### Wiring, controls and startup

With the electrical connections made, we wire and set up the thermostat for the system’s stages and backup heat. At startup we measure airflow and static pressure and set the blower for your ducts, verify the refrigerant charge, test the drain and float switch, and confirm the heat strip and defrost. The readings go on your startup record so a later visit can compare against them. The [installation process guide](https://sweetolivenolaheatpumps.com/guide/heat-pump-installation-process/) has the full sequence.

## What a new installation costs

The price follows the scope, and the scope follows the house.

**Sweet Olive's typical range for a residential ducted heat pump installation is $4,250 to $11,750.** We set your price after the site visit and write it into your estimate line by line, so you can see what each part of the scope adds.

What moves your price

- **Capacity and efficiency tier.** Two-stage and variable-speed equipment costs more than single-stage.
- **How much ductwork.** A whole new duct system is the biggest swing; sound existing ducts lower it.
- **Where the air handler goes.** An attic platform adds the secondary pan and float switch.
- **Electrical work.** New circuits are routine; a panel upgrade is a separate line.
- **The outdoor spot.** Line-set length and a raised stand on a low lot.
- **Access.** Low attic headroom or a tight crawlspace adds labor.
- **Permit and controls.** The permit for your address and a thermostat that matches the equipment.

Connections at the outdoor unit: each part of the job is its own line on your estimate.

### Rebates and tax credits

If you have an Entergy New Orleans residential account, the Energy Smart program offers rebates on qualifying equipment installed by a participating contractor, within its current funding period. The federal 25C tax credit no longer applies to equipment placed in service after December 31, 2025, according to IRS guidance. Our [cost guide](https://sweetolivenolaheatpumps.com/guide/heat-pump-cost/) breaks down a typical budget, the [cost estimator](https://sweetolivenolaheatpumps.com/tools/heat-pump-cost-estimator/) builds a starting budget for your house, and the [rebate guide](https://sweetolivenolaheatpumps.com/guide/heat-pump-rebates/) explains eligibility.

## What your installation includes

Your written estimate lists each of these for your house, and names anything we leave out.

- The room-by-room load calculation and the equipment choice that follows from it
- Outdoor heat pump, matched indoor air handler and the electric backup heat your heating load calls for
- Supply and return ductwork, new or modified, sealed at every connection
- Insulated copper line set, pressure test, evacuation and refrigerant charge
- Condensate drain, plus a secondary pan and float switch wherever the air handler sits above a ceiling
- Pad or stand, outdoor disconnect and the new circuits the equipment needs
- A thermostat set up for the system's stages and backup heat
- The permit and inspection steps for your address
- Startup readings, equipment records and a walk-through of the controls
- Cleanup, and removal of any window units we take out

## Three ways to cool and heat a house with no central system

Starting from window units and space heaters, these are the real choices. We install the first one.

*Ducted heat pump, central air with a gas furnace, and room units compared*

| Option | What goes in | How it heats | Summer moisture | What to plan for |
| --- | --- | --- | --- | --- |
| Ducted heat pump | An outdoor unit, an indoor air handler, ducts to every room and one thermostat | The same equipment runs in reverse, with a small electric backup for the coldest mornings | Long, steady runs at low output dry the whole house | A duct route, attic or closet space for the air handler, and new circuits |
| Central air with a gas furnace | An outdoor condenser, a furnace with a cooling coil, ducts and venting | Gas heat from the furnace | Depends on the equipment and how it is sized, as with any ducted system | A gas line, venting and combustion checks on top of the duct work |
| Window or room units | One unit per room, no ducts | Separate heaters, room by room | Only rooms with a unit; halls and baths stay damp | An outlet in each room, noise and blocked windows |

When the house has room for an air handler and a route for ducts, a ducted heat pump handles cooling, heating and moisture with one system and one thermostat. If the visit finds no workable duct route, we tell you before you commit to anything.

## How your installation runs

Six stops from your first message to the day you take over the thermostat.

1. Tell us about the house The address, the rooms that bother you and what cools and heats them now. Photos of the panel and the attic opening help us prepare.
2. We visit and measure We walk the rooms, the attic or crawlspace, the panel and the yard, and take the measurements the load calculation needs.
3. Your written estimate Equipment, duct layout, electrical work, permit steps and exclusions, with the price that follows from them.
4. Permit and scheduling Equipment is ordered and the permit is handled as your estimate states before the work days are booked.
5. The work days Air handler and ducts first, then the outdoor unit, line set, drain and wiring, with your rooms protected as we go.
6. Startup and handover Pressure test, evacuation, charge, airflow and controls, then the readings and a walk-through of the thermostat.

## Questions we hear about this work

### How long does a new heat pump installation take?

For a single-story house that needs all new ductwork, plan on about three working days. The first goes to the air handler and ducts, the second to the outdoor unit, line set, drain and wiring, and the third to testing, startup and handover. Sound ducts that can be reused shorten it. The permit inspection is booked after the work, and your written estimate gives the schedule for your house.

### Can you put a ducted heat pump in a house that has never had ducts?

Yes, when the house has a route for them. In a raised house the attic can carry the supply runs to ceiling registers, with the air handler on a platform up there or in a closet. We check headroom, the attic opening, the joist layout and a spot for a central return before we draw a layout. If there's no workable route, we say so at the visit.

### Will a heat pump keep up with a New Orleans summer?

In cooling mode a heat pump runs the same refrigeration cycle as a central air conditioner, so a correctly sized one cools the house the same way. What decides comfort in a humid summer is sizing and setup. Oversized equipment chills the air fast and shuts off before it removes much moisture, so we size from the room loads and set the airflow and controls for moisture removal.

### Do I need a bigger electrical panel for a heat pump?

Not always. The heat pump and the air handler each need a dedicated circuit, and the electric backup heat often draws more than the heat pump itself. We check the panel's rating, its open spaces and what is already on it at the first visit. If the panel can carry the new circuits, the estimate includes them; if it can't, we explain the upgrade before you decide.

### Can I get a rebate on a new heat pump in New Orleans?

If you have an Entergy New Orleans residential account, check the Energy Smart program, which offers rebates on qualifying heat pump equipment installed by a participating contractor. The program sets which projects and efficiency ratings qualify, so we check your account and the proposed equipment against its current rules before anything comes off your budget.